Standard: | IEC 60598-2-13 Clause 13.6.1, 13.6.2 | Customize: | OEM, ODM |
---|---|---|---|
Controller: | Mitsubishi PLC | Display: | Touch Screen |
Station: | 1 Station | Test Object: | Ground Accessed Luminaires |
Test: | Static Load Test And Torque Test | Max. Load: | 20KN |
Rubber Punch: | Diameter 50mm, Thickness 50mm | Maintain Time: | 5-10s For Torque Test, 1min For Static Load Test |
High Light: | 20KN Led Testing Equipment , IEC 60598-2-13 Led Testing Equipment , IEC 60598-2-13 force testing equipment |
IEC60598-2-13 Ground Recessed Luminaires Light Testing Equipment
Main technical parameters:
Power supply | 380V 50Hz |
Test object | ground accessed luminaires |
Test | static load test and torque test |
Max. load | 20KN |
Rubber punch | diameter 50mm, thickness 50mm |
Maintain time | 5-10s for torque test, 1min for static load test |
Station | 1 station |
Standard | IEC 60598-2-13 Clause 13.6.1, 13.6.2 |
Control | Mitsubishi PLC |
Display | Touch screen |
Production introduction:
This test equipment conforms to IEC 60598-2-13 clause 13.6.1 and clause 13.6.2 standard requirements.
It is used for the ground accessed luminaires static load test and torque test.
This equipment is controlled by PLC electrical system, the whole operation is controlled on the touch screen, all the parameters can be preset on the touch screen, include every selection mode of the kettle, the touch screen with the functions of manual operation, automatic operation and real-time display.
IEC 60598-2-13
13.6.1 Resistance to static load
Luminaires shall withstand the minimum static load according to the manufacturer’s instruction.
13.6.2 Resistance too torque and shear loads
Luminaires designed to be used in areas where motor vehicles may circulate, carriageways, parking areas, etc.
shall withstand the forces exerted by a turning, breaking or accelerating tire.
Test details please reference to standard discription.