Standard: | IEC60245-1 | Function: | For Checking Mechanical Strength Of Completed Flexible Cables |
---|---|---|---|
A, B Clamping Head Initial Distance: | 200mm | A And B, Shall Be Located At A Height Above Ground Level: | At Least 1.5m |
Sample Length: | 3±0.05m | The Cable Being Turned In The Clamp: | 180° |
Number Of Testing Times: | 2 | Test Sample: | Ar-welding Electrode Cables And Lift Cables |
High Light: | IEC60245 Cable Testing Equipment , 200mm Cable Testing Equipment , CNAS static flexibility test |
IEC60245 Static Flexibility Tester For Testing Cable Mechanical Strength
Product Information:
This apparatus conforms to IEC60245-1 Rubber insulated cables-Rated voltages up to and including 450/750 V-Part 1:General requirements, IEC60245-2 clause 3.2 and Figure 2 Rubber insulated cables-Rated voltages up to and including 450/750 V-Part 2: Test methods.
It is used for checking mechanical strength of completed flexible cables. This test does not apply to flexible cables with cores of nominal cross-sectional area greater than 4mm2 and cables having more than 18 cores laid up in more than two concentric layers.
Technical Parameters:
A, B clamping head initial distance | 200mm |
A and B, shall be located at a height above ground level | At least 1.5m |
Sample length | 3±0.05m |
The cable being turned in the clamp | 180° |
Number of testing times | 2 |
Application:
The apparatus is used for the static flexibility test for ar-welding electrode cables
It is used for the static flexibility test for lift cables
Standards: