Standard: | IEC60950 | Usage: | Flame Testing Equipment |
---|---|---|---|
Glowing Filament: | Ф4mm ± 0.04mm Ni/Cr(80/20) Special Standard Ring Shape,horizontal Standing | Thermocouple: | 0.5mm Import K Thermocouple,the Temperature Resistance Of Armour Is 1100 ℃ ( Better Than The Standard Of 1050 ℃ ) |
Ohmic Heating Temperature Of Glowing Filament: | 500 ℃ ~ 960 ℃ ( Digital Display Can Be Preset ) ,temperature Fluctuation < 3 ℃ | Specimen Pressure On Glowing Filament: | 1.0N±0.1N( Adjustable ),better Than Standard 1.0N±0.2N |
Maximum Depth Of Heating: | 7mm ± 0.5mm | Specimen Movement Speed: | 10mm /s ~ 25mm /s |
Power: | 1kVA 220V /50Hz& 110V /60Hz | Volume Of Test Site: | ≥ 0.5m 3 Black Background ,background Illuminance ≤ 20Lx |
High Light: | IEC60695 Flammability Test Equipment , TUV Flammability Test Equipment , IEC60950 glow wire test apparatus |
IEC60695 Glow Wire Test Apparatus Flammability Testing Equipment
Test principle and products feature:
Test principle: the glowing filament whose material and shape is required(Ni80/Cr20)is heated to the testing temperature of 550 ℃ ~ 960 ℃ for 1 min by using the glow wire tester with large current. Then using required pressure (1.0N) vertically burns the test sample for 30s. By observing whether the test sample and bedding object ignite or the burning time, the users can judge the ignition danger of electric and electronic products. It is used for the ignition test, ignition temperature (GWIT) test, flammability test and flammability index (GWFI) test of solid insulating material and other solid combustible material.
Products feature: Adopting solenoid valve switch to control the burning depth of test sample and equipped with measuring gauge, this device has the features of exact and rapid. The test sample will break away automatically from glowing filament after reaching the set time. Adopting the original imported UK LAB K type armour(0.5) whose temperature resistance is up to 1100°(exceed 1050°of standard requirement) , this device is with accuracy temperature control.
Technical parameters:
Glowing filament | Ф4mm ± 0.04mm Ni/Cr(80/20) special standard ring shape,horizontal standing |
Thermocouple | 0.5mm import K thermocouple,the temperature resistance of armour is 1100 ℃ ( better than the standard of 1050 ℃ ) |
ohmic heating temperature of glowing filament | 500 ℃ ~ 960 ℃ ( digital display can be preset ) ,temperature fluctuation < 3 ℃ |
Specimen pressure on glowing filament | 1.0N±0.1N( adjustable ),better than standard 1.0N±0.2N |
Maximum depth of heating | 7mm ± 0.5mm |
Specimen movement speed | 10mm /s ~ 25mm /s |
Testing time | 30s±0.1s(1s ~ 999.9s digital display preset ) |
Thickness of ignite bedding board | thickness10mm ,white pine board cover 12g /m 2 ~ 30g /m 2 standard silk paper |
Volume of test site | ≥ 0.5m 3 black background ,background illuminance ≤ 20Lx |
Dimension and weight | W: 1100mm × D: 550mm × H: 1200mm ,gas vent:100mm ,140kg |
Power | 1kVA 220V /50Hz& 110V /60Hz |
Product details:
This device is manufactured according to the standard of IEC60695-2-10, IEC60695-2-13.
It also conforms to the standard requirement of UL746A. This device simulates the thermal stress test of glowing component or heat source like overload resistance or ignition source which is caused in s short time. It is suitable for electric and electronic products, household appliances and other material to do fire hazard testing. It is also used in the No flame ignition source fire test to test initiation temperature and flammability index of related glowing filament.
Testing pictures: