Stainless Steel Plug Socket Tester For Torsion Test

Material:Stainless SteelStandards:BS1363 Figure 33
Name:Apparatus For Torsion Test On PinsFunction:For Torsion Test On Pins
Warranty:24 MonthsBS1363 Figure 32:Apparatus For Tests On Adaptor Pins
BS1363 Figure 33:Apparatus For Torsion Test On PinsBS1363 Figure 35:Simulated Plug And Cord Devices
High Light:Stainless Steel Plug Socket Tester ,  BS1363 Figure 33 Plug Socket Tester ,  Pins Torsion Test Apparatus

BS1363 Figure 33 Apparatus For Torsion Test On Pins

Parameters:

StandardsBS1363 Figure 33
FunctionFor Torsion Test on Pins
Clamp for adaptor1 set
Torque tube2
MaterialStainless steel

BS1363 List of references

Figure 33-apparatus for torsion test on pins
Figure 34-test plug
Figure 35-simulated plug and cord devices
Figure 36-apparatus for calibration of turning moment of
simulated plug
Figure 37-turning moment apparatus
Figure 38-solid links for test on fuse clips

Figure1 test pin
Figure 2a)-apparatus for mechanical strength test on resilient covers
Figure 2b)-hardwood block for Figure 2a)
Figure 3-disposition of socket contacts
Figure 4-dimensions and disposition of pins
Figure 5-gauge for adaptor pins
Figure 6-apparatus for testing plug cover fixing screws
Figure 7-mounting plate
Figure 8-plug pin deflection test apparatus for resilient adaptors
Figure 9-apparatus for abrasion test on insulating sleeves of plug pins
Figure 10-apparatus for pressure test at high temperatures
Figure 11-GO gauge for socket-outlet
Figure 12-contact test gauge
Figure 13-test apparatus and circuit for use with contact and non-contact test gauges
Figure 14-non-contact test gauge
Figure 16-withdrawal pull gauges for effectiveness of contact
Figure17a)-Test apparatus for temperature-rise- test
Figure 17b)-dummy front plate for temperature-rise test
Figure 18-apparatus for flexing test
Figure 19-solid link for test on fuse clips
Figure 20–tumbling barrel
Figure 21-pendulum impact test
Figure 23-apparatus for pressure test
Figure 24-apparatus for ball pressure test
Figure 28-calibrated link
Figure 29-calibration jig for calibrated link
Figure 30-test plug for temperature rise
Figure 32-apparatus for tests on adaptor pins
 

Position a pin on the fixed anyil of the apparatus, as shown in Figure 33, with the wideat aurface in the
horizontal plane. Bring the movable anvil to rest against the upper surface of the pin This quiescent
position shall be taken as the datum point Apply a force to the movable anvll by any conventent method
such that the pin is strained at a rate not exceeding 10 m/min Measure the applied force when the
movement of the anvil from the datum point reache: 1.5 -01 min The test hall be made zeparately on

12.11.4 Adaptor plug pins shall have adequate strength to withstand the stresses of normal use.
12.11.4.1 For solid pins. conformity shall be checked by the following test.

Position a pin on the fixed anyil of the apparatus, as shown in Figure 33, with the wideat aurface in the
horizontal plane. Bring the movable anvil to rest against the upper surface of the pin This quiescent
position shall be taken as the datum point Apply a force to the movable anvll by any conventent method
such that the pin is strained at a rate not exceeding 10 m/min Measure the applied force when the
movement of the anvil from the datum point reache: 1.5 -01 min The test hall be made zeparately on

12.11.4 Adaptor plug pins shall have adequate strength to withstand the stresses of normal use.
12.11.4.1 For solid pins. conformity shall be checked by the following test.